------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | cls | attribute | phys_quant_type | decl_cls | description | rdl | is_proteus_generic_attribute | ========================================================================================================================================================================================================================================================================================================================================================================= | "Agitator" | "DesignShaftPower" | "Power" | "Agitator" | "The design shaft power of the ." | | true | | "Agitator" | "DesignRotationalSpeed" | "RotationalSpeed" | "Agitator" | "The design rotational speed of the ." | | true | | "AgitatorRotor" | "Diameter" | "Length" | "AgitatorRotor" | "The diameter of the ." | | true | | "AgitatorRotor" | "LengthToMountingFlange" | "Length" | "AgitatorRotor" | "The length to the mounting flange of the ." | | true | | "AirCoolingSystem" | "DesignPower" | "Power" | "AirCoolingSystem" | "The design power of the ." | | true | | "AirCoolingSystem" | "DesignShaftPower" | "Power" | "AirCoolingSystem" | "The design shaft power of the ." | | true | | "AirCoolingSystem" | "DesignRotationalSpeed" | "RotationalSpeed" | "AirCoolingSystem" | "The design rotational speed of the ." | | true | | "AirCoolingSystem" | "DesignHeatTransferArea" | "Area" | "HeatExchanger" | "The design heat transfer area of the ." | | true | | "AirCoolingSystem" | "DesignHeatTransferCoefficient" | "HeatTransferCoefficient" | "HeatExchanger" | "The design heat transfer coefficient of the ." | | true | | "AirCoolingSystem" | "DesignHeatFlowRate" | "Power" | "HeatExchanger" | "The heat flow rate for which the is designed." | | true | | "AirEjector" | "DesignCapacityMotiveFluid" | "VolumeFlowRate" | "AirEjector" | "The design capacity for the motive fluid of the ." | | true | | "AirEjector" | "DifferentialPressure" | "Pressure" | "Compressor" | "The differential pressure of the ." | | true | | "AirEjector" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Compressor" | "The volume flow rate for which the is designed." | | true | | "AngleBallValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "AngleBallValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "AngleGlobeValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "AngleGlobeValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "AnglePlugValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "AnglePlugValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "AngleValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "AngleValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "AxialCompressor" | "DesignShaftPower" | "Power" | "AxialCompressor" | "The design shaft power of the ." | | true | | "AxialCompressor" | "DesignRotationalSpeed" | "RotationalSpeed" | "AxialCompressor" | "The design rotational speed of the ." | | true | | "AxialCompressor" | "DifferentialPressure" | "Pressure" | "Compressor" | "The differential pressure of the ." | | true | | "AxialCompressor" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Compressor" | "The volume flow rate for which the is designed." | | true | | "BallValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "BallValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "BlindFlange" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "BlindFlange" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "BreatherValve" | "SetPressureHigh" | "Pressure" | "SafetyValveOrFitting" | "The high pressure at which the is activated." | | true | | "BreatherValve" | "SetPressureLow" | "Pressure" | "SafetyValveOrFitting" | "The low pressure at which the is activated." | | true | | "ButterflyValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "ButterflyValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "CentrifugalCompressor" | "DesignShaftPower" | "Power" | "CentrifugalCompressor" | "The design shaft power of the ." | | true | | "CentrifugalCompressor" | "DesignRotationalSpeed" | "RotationalSpeed" | "CentrifugalCompressor" | "The design rotational speed of the ." | | true | | "CentrifugalCompressor" | "DifferentialPressure" | "Pressure" | "Compressor" | "The differential pressure of the ." | | true | | "CentrifugalCompressor" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Compressor" | "The volume flow rate for which the is designed." | | true | | "CentrifugalPump" | "DesignShaftPower" | "Power" | "CentrifugalPump" | "The design shaft power of the ." | | true | | "CentrifugalPump" | "DesignRotationalSpeed" | "RotationalSpeed" | "CentrifugalPump" | "The design rotational speed of the ." | | true | | "CentrifugalPump" | "DesignPressureHead" | "Length" | "Pump" | "The design pressure head of the ." | | true | | "CentrifugalPump" | "DifferentialPressure" | "Pressure" | "Pump" | "The differential pressure of the ." | | true | | "CentrifugalPump" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Pump" | "The volume flow rate for which the is designed." | | true | | "Chamber" | "Height" | "Length" | "Chamber" | "The height of the ." | | true | | "Chamber" | "InsideDiameter" | "Length" | "Chamber" | "The inside diameter of the ." | | true | | "Chamber" | "Length" | "Length" | "Chamber" | "The length of the ." | | true | | "Chamber" | "NominalDiameter" | "Length" | "Chamber" | "The nominal diameter of the , given as a length. See also ." | | true | | "Chamber" | "Width" | "Length" | "Chamber" | "The width of the ." | | true | | "Chamber" | "LowerLimitDesignPressure" | "Pressure" | "Chamber" | "The lowest pressure for which the is designed." | | true | | "Chamber" | "UpperLimitDesignPressure" | "Pressure" | "Chamber" | "The highest pressure for which the is designed." | | true | | "Chamber" | "LowerLimitDesignTemperature" | "Temperature" | "Chamber" | "The lowest temperature for which the is designed." | | true | | "Chamber" | "UpperLimitDesignTemperature" | "Temperature" | "Chamber" | "The highest temperature for which the is designed." | | true | | "CheckValve" | "InsulationThickness" | "Length" | "CheckValve" | "The insulation thickness of the ." | | true | | "CheckValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "CheckValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "ClampedFlangeCoupling" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "ClampedFlangeCoupling" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "ColumnPackingsArrangement" | "Height" | "Length" | "ColumnPackingsArrangement" | "The height of the ." | | true | | "ColumnSection" | "Height" | "Length" | "ColumnSection" | "The height of the ." | | true | | "ColumnSection" | "InsideDiameter" | "Length" | "ColumnSection" | "The inside diameter of the ." | | true | | "Compensator" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "Compensator" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "Compressor" | "DifferentialPressure" | "Pressure" | "Compressor" | "The differential pressure of the ." | | true | | "Compressor" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Compressor" | "The volume flow rate for which the is designed." | | true | | "ConicalStrainer" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "ConicalStrainer" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "Displacer" | "VolumePerStroke" | "Volume" | "Displacer" | "The volume per stroke of the ." | | true | | "EjectorPump" | "DesignCapacityMotiveFluid" | "VolumeFlowRate" | "EjectorPump" | "The design capacity for the motive fluid of the ." | | true | | "EjectorPump" | "DesignPressureHead" | "Length" | "Pump" | "The design pressure head of the ." | | true | | "EjectorPump" | "DifferentialPressure" | "Pressure" | "Pump" | "The differential pressure of the ." | | true | | "EjectorPump" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Pump" | "The volume flow rate for which the is designed." | | true | | "ElectricHeater" | "DesignPower" | "Power" | "ElectricHeater" | "The design power of the ." | | true | | "ElectricHeater" | "DesignHeatTransferArea" | "Area" | "HeatExchanger" | "The design heat transfer area of the ." | | true | | "ElectricHeater" | "DesignHeatTransferCoefficient" | "HeatTransferCoefficient" | "HeatExchanger" | "The design heat transfer coefficient of the ." | | true | | "ElectricHeater" | "DesignHeatFlowRate" | "Power" | "HeatExchanger" | "The heat flow rate for which the is designed." | | true | | "ElectromagneticFlowMeter" | "InsulationThickness" | "Length" | "InlinePrimaryElement" | "The insulation thickness of the ." | | true | | "ElectromagneticFlowMeter" | "LowerLimitHeatTracingTemperature" | "Temperature" | "InlinePrimaryElement" | "The temperature that a heat tracing system must ensure for the . " | | true | | "FilterUnit" | "FilterArea" | "Area" | "FilterUnit" | | | true | | "FilterUnit" | "LowerLimitPermeableParticleDiameter" | "Length" | "FilterUnit" | | | true | | "FilterUnit" | "UpperLimitPermeableParticleDiameter" | "Length" | "FilterUnit" | | | true | | "FilterUnit" | "Efficiency" | "Percentage" | "FilterUnit" | | | true | | "FilterUnit" | "LowerLimitAllowableSolidsConcentration" | "Percentage" | "FilterUnit" | | | true | | "FilterUnit" | "UpperLimitAllowableSolidsConcentration" | "Percentage" | "FilterUnit" | | | true | | "FlameArrestor" | "SetPressureHigh" | "Pressure" | "SafetyValveOrFitting" | "The high pressure at which the is activated." | | true | | "FlameArrestor" | "SetPressureLow" | "Pressure" | "SafetyValveOrFitting" | "The low pressure at which the is activated." | | true | | "Flange" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "Flange" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "FlangedConnection" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "FlangedConnection" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "FlowDetector" | "InsulationThickness" | "Length" | "InlinePrimaryElement" | "The insulation thickness of the ." | | true | | "FlowDetector" | "LowerLimitHeatTracingTemperature" | "Temperature" | "InlinePrimaryElement" | "The temperature that a heat tracing system must ensure for the . " | | true | | "FlowNozzle" | "InsulationThickness" | "Length" | "InlinePrimaryElement" | "The insulation thickness of the ." | | true | | "FlowNozzle" | "LowerLimitHeatTracingTemperature" | "Temperature" | "InlinePrimaryElement" | "The temperature that a heat tracing system must ensure for the . " | | true | | "Funnel" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "Funnel" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "GasFilter" | "DesignShaftPower" | "Power" | "GasFilter" | "The design shaft power of the ." | | true | | "GasFilter" | "UpperLimitAllowableDesignPressureDrop" | "Pressure" | "GasFilter" | "The maximum allowable design pressure drop of the ." | | true | | "GasFilter" | "DesignRotationalSpeed" | "RotationalSpeed" | "GasFilter" | "The design rotational speed of the ." | | true | | "GasFilter" | "Capacity(volumeFlowRate)" | "VolumeFlowRate" | "GasFilter" | "The handling flow rate for which the is designed." | | true | | "GateValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "GateValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "GlobeCheckValve" | "InsulationThickness" | "Length" | "CheckValve" | "The insulation thickness of the ." | | true | | "GlobeCheckValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "CheckValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "GlobeValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "GlobeValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "HeatExchanger" | "DesignHeatTransferArea" | "Area" | "HeatExchanger" | "The design heat transfer area of the ." | | true | | "HeatExchanger" | "DesignHeatTransferCoefficient" | "HeatTransferCoefficient" | "HeatExchanger" | "The design heat transfer coefficient of the ." | | true | | "HeatExchanger" | "DesignHeatFlowRate" | "Power" | "HeatExchanger" | "The heat flow rate for which the is designed." | | true | | "Hose" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "Hose" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "IlluminatedSightGlass" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "IlluminatedSightGlass" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "Impeller" | "Diameter" | "Length" | "Impeller" | "The diameter of the ." | | true | | "InLineMixer" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "InLineMixer" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "InlinePrimaryElement" | "InsulationThickness" | "Length" | "InlinePrimaryElement" | "The insulation thickness of the ." | | true | | "InlinePrimaryElement" | "LowerLimitHeatTracingTemperature" | "Temperature" | "InlinePrimaryElement" | "The temperature that a heat tracing system must ensure for the . " | | true | | "Kneader" | "DesignShaftPower" | "Power" | "Kneader" | "The design shaft power of the ." | | true | | "Kneader" | "UpperLimitAllowableDesignPressureDrop" | "Pressure" | "Kneader" | "The maximum allowable design pressure drop of the ." | | true | | "Kneader" | "DesignRotationalSpeed" | "RotationalSpeed" | "Kneader" | "The design rotational speed of the ." | | true | | "LineBlind" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "LineBlind" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "LiquidFilter" | "DesignShaftPower" | "Power" | "LiquidFilter" | "The design shaft power of the ." | | true | | "LiquidFilter" | "UpperLimitAllowableDesignPressureDrop" | "Pressure" | "LiquidFilter" | "The maximum allowable design pressure drop of the ." | | true | | "LiquidFilter" | "DesignRotationalSpeed" | "RotationalSpeed" | "LiquidFilter" | "The design rotational speed of the ." | | true | | "LiquidFilter" | "Capacity(volumeFlowRate)" | "VolumeFlowRate" | "LiquidFilter" | "The handling flow rate for which the is designed." | | true | | "NeedleValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "NeedleValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "OfflinePrimaryElement" | "InsulationThickness" | "Length" | "OfflinePrimaryElement" | "The insulation thickness of the ." | | true | | "OfflinePrimaryElement" | "LowerLimitHeatTracingTemperature" | "Temperature" | "OfflinePrimaryElement" | "The temperature that a heat tracing system must ensure for the . " | | true | | "OrificePlate" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "OrificePlate" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "Penetration" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "Penetration" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PipeCoupling" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "PipeCoupling" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PipeFitting" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "PipeFitting" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PipeFlangeSpacer" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "PipeFlangeSpacer" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PipeFlangeSpade" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "PipeFlangeSpade" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PipeReducer" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "PipeReducer" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PipeTee" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "PipeTee" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PipingNetworkSegment" | "InsulationThickness" | "Length" | "PipingNetworkSegment" | "The insulation thickness of the ." | | true | | "PipingNetworkSegment" | "Inclination" | "Percentage" | "PipingNetworkSegment" | "The inclination (slope) of the in percent." | | true | | "PipingNetworkSegment" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipingNetworkSegment" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PipingNetworkSegment" | "OperatingTemperature" | "Temperature" | "PipingNetworkSegment" | "The operating temperature of the ." | | true | | "PipingNetworkSystem" | "InsulationThickness" | "Length" | "PipingNetworkSystem" | "The insulation thickness of the ." | | true | | "PipingNetworkSystem" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipingNetworkSystem" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PlateAndShellHeatExchanger" | "DesignHeatTransferArea" | "Area" | "HeatExchanger" | "The design heat transfer area of the ." | | true | | "PlateAndShellHeatExchanger" | "DesignHeatTransferCoefficient" | "HeatTransferCoefficient" | "HeatExchanger" | "The design heat transfer coefficient of the ." | | true | | "PlateAndShellHeatExchanger" | "DesignHeatFlowRate" | "Power" | "HeatExchanger" | "The heat flow rate for which the is designed." | | true | | "PlateAndShellHeatExchanger" | "PlateHeight" | "Length" | "PlateAndShellHeatExchanger" | "The height of the plates in the ." | | true | | "PlateAndShellHeatExchanger" | "PlateWidth" | "Length" | "PlateAndShellHeatExchanger" | "The width of the plates in the ." | | true | | "PlugValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "PlugValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PositiveDisplacementFlowMeter" | "InsulationThickness" | "Length" | "InlinePrimaryElement" | "The insulation thickness of the ." | | true | | "PositiveDisplacementFlowMeter" | "LowerLimitHeatTracingTemperature" | "Temperature" | "InlinePrimaryElement" | "The temperature that a heat tracing system must ensure for the . " | | true | | "PressureVessel" | "CylinderLength" | "Length" | "PressureVessel" | "The cylinder length of the ." | | true | | "PressureVessel" | "NominalCapacity(Volume)" | "Volume" | "Vessel" | "The nominal volumetric capacity of the ." | | true | | "ProcessColumn" | "NominalCapacity(Volume)" | "Volume" | "ProcessColumn" | "The nominal volumetric capacity of the ." | | true | | "Pump" | "DesignPressureHead" | "Length" | "Pump" | "The design pressure head of the ." | | true | | "Pump" | "DifferentialPressure" | "Pressure" | "Pump" | "The differential pressure of the ." | | true | | "Pump" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Pump" | "The volume flow rate for which the is designed." | | true | | "ReciprocatingCompressor" | "DifferentialPressure" | "Pressure" | "Compressor" | "The differential pressure of the ." | | true | | "ReciprocatingCompressor" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Compressor" | "The volume flow rate for which the is designed." | | true | | "ReciprocatingCompressor" | "DesignShaftPower" | "Power" | "ReciprocatingCompressor" | "The design shaft power of the ." | | true | | "ReciprocatingCompressor" | "DesignRotationalSpeed" | "RotationalSpeed" | "ReciprocatingCompressor" | "The design rotational speed of the ." | | true | | "ReciprocatingPump" | "DesignPressureHead" | "Length" | "Pump" | "The design pressure head of the ." | | true | | "ReciprocatingPump" | "DifferentialPressure" | "Pressure" | "Pump" | "The differential pressure of the ." | | true | | "ReciprocatingPump" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Pump" | "The volume flow rate for which the is designed." | | true | | "ReciprocatingPump" | "DesignShaftPower" | "Power" | "ReciprocatingPump" | "The design shaft power of the ." | | true | | "ReciprocatingPump" | "DesignRotationalSpeed" | "RotationalSpeed" | "ReciprocatingPump" | "The design rotational speed of the ." | | true | | "ReciprocatingPump" | "DesignCapacityMotiveFluid" | "VolumeFlowRate" | "ReciprocatingPump" | "The design capacity for the motive fluid of the ." | | true | | "RotaryCompressor" | "DifferentialPressure" | "Pressure" | "Compressor" | "The differential pressure of the ." | | true | | "RotaryCompressor" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Compressor" | "The volume flow rate for which the is designed." | | true | | "RotaryCompressor" | "DesignShaftPower" | "Power" | "RotaryCompressor" | "The design shaft power of the ." | | true | | "RotaryCompressor" | "DesignRotationalSpeed" | "RotationalSpeed" | "RotaryCompressor" | "The design rotational speed of the ." | | true | | "RotaryMixer" | "DesignShaftPower" | "Power" | "RotaryMixer" | "The design shaft power of the ." | | true | | "RotaryMixer" | "UpperLimitAllowableDesignPressureDrop" | "Pressure" | "RotaryMixer" | "The maximum allowable design pressure drop of the ." | | true | | "RotaryMixer" | "DesignRotationalSpeed" | "RotationalSpeed" | "RotaryMixer" | "The design rotational speed of the ." | | true | | "RotaryPump" | "DesignPressureHead" | "Length" | "Pump" | "The design pressure head of the ." | | true | | "RotaryPump" | "DifferentialPressure" | "Pressure" | "Pump" | "The differential pressure of the ." | | true | | "RotaryPump" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Pump" | "The volume flow rate for which the is designed." | | true | | "RotaryPump" | "DesignShaftPower" | "Power" | "RotaryPump" | "The design shaft power of the ." | | true | | "RotaryPump" | "DesignRotationalSpeed" | "RotationalSpeed" | "RotaryPump" | "The design rotational speed of the ." | | true | | "RuptureDisc" | "SetPressureHigh" | "Pressure" | "SafetyValveOrFitting" | "The high pressure at which the is activated." | | true | | "RuptureDisc" | "SetPressureLow" | "Pressure" | "SafetyValveOrFitting" | "The low pressure at which the is activated." | | true | | "SafetyValveOrFitting" | "SetPressureHigh" | "Pressure" | "SafetyValveOrFitting" | "The high pressure at which the is activated." | | true | | "SafetyValveOrFitting" | "SetPressureLow" | "Pressure" | "SafetyValveOrFitting" | "The low pressure at which the is activated." | | true | | "ShellAndTubeHeatExchanger" | "DesignHeatTransferArea" | "Area" | "HeatExchanger" | "The design heat transfer area of the ." | | true | | "ShellAndTubeHeatExchanger" | "DesignHeatTransferCoefficient" | "HeatTransferCoefficient" | "HeatExchanger" | "The design heat transfer coefficient of the ." | | true | | "ShellAndTubeHeatExchanger" | "DesignHeatFlowRate" | "Power" | "HeatExchanger" | "The heat flow rate for which the is designed." | | true | | "ShutOffValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "ShutOffValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "SightGlass" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "SightGlass" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "Silencer" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "Silencer" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "Silo" | "NominalCapacity(Volume)" | "Volume" | "Vessel" | "The nominal volumetric capacity of the ." | | true | | "SpecialCompressor" | "DifferentialPressure" | "Pressure" | "Compressor" | "The differential pressure of the ." | | true | | "SpecialCompressor" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Compressor" | "The volume flow rate for which the is designed." | | true | | "SpecialCompressor" | "DesignShaftPower" | "Power" | "SpecialCompressor" | "The design shaft power of the ." | | true | | "SpecialCompressor" | "DesignRotationalSpeed" | "RotationalSpeed" | "SpecialCompressor" | "The design rotational speed of the ." | | true | | "SpecialCompressor" | "DesignCapacityMotiveFluid" | "VolumeFlowRate" | "SpecialCompressor" | "The design capacity for the motive fluid of the ." | | true | | "SpecialPump" | "DesignPressureHead" | "Length" | "Pump" | "The design pressure head of the ." | | true | | "SpecialPump" | "DifferentialPressure" | "Pressure" | "Pump" | "The differential pressure of the ." | | true | | "SpecialPump" | "DesignVolumeFlowRate" | "VolumeFlowRate" | "Pump" | "The volume flow rate for which the is designed." | | true | | "SpecialPump" | "DesignShaftPower" | "Power" | "SpecialPump" | "The design shaft power of the ." | | true | | "SpecialPump" | "DesignRotationalSpeed" | "RotationalSpeed" | "SpecialPump" | "The design rotational speed of the ." | | true | | "SpecialPump" | "DesignCapacityMotiveFluid" | "VolumeFlowRate" | "SpecialPump" | "The design capacity for the motive fluid of the ." | | true | | "SpecialVessel" | "CylinderLength" | "Length" | "SpecialVessel" | "The cylinder length of the ." | | true | | "SpecialVessel" | "NominalCapacity(Volume)" | "Volume" | "Vessel" | "The nominal volumetric capacity of the ." | | true | | "SpiralHeatExchanger" | "DesignHeatTransferArea" | "Area" | "HeatExchanger" | "The design heat transfer area of the ." | | true | | "SpiralHeatExchanger" | "DesignHeatTransferCoefficient" | "HeatTransferCoefficient" | "HeatExchanger" | "The design heat transfer coefficient of the ." | | true | | "SpiralHeatExchanger" | "DesignHeatFlowRate" | "Power" | "HeatExchanger" | "The heat flow rate for which the is designed." | | true | | "SpringLoadedAngleGlobeSafetyValve" | "SetPressureHigh" | "Pressure" | "SafetyValveOrFitting" | "The high pressure at which the is activated." | | true | | "SpringLoadedAngleGlobeSafetyValve" | "SetPressureLow" | "Pressure" | "SafetyValveOrFitting" | "The low pressure at which the is activated." | | true | | "SpringLoadedGlobeSafetyValve" | "SetPressureHigh" | "Pressure" | "SafetyValveOrFitting" | "The high pressure at which the is activated." | | true | | "SpringLoadedGlobeSafetyValve" | "SetPressureLow" | "Pressure" | "SafetyValveOrFitting" | "The low pressure at which the is activated." | | true | | "StaticMixer" | "UpperLimitAllowableDesignPressureDrop" | "Pressure" | "StaticMixer" | "The maximum allowable design pressure drop of the ." | | true | | "SteamTrap" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "SteamTrap" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "StraightwayValve" | "InsulationThickness" | "Length" | "ShutOffValve" | "The insulation thickness of the ." | | true | | "StraightwayValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "ShutOffValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "Strainer" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "Strainer" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "SubTaggedColumnSection" | "Height" | "Length" | "ColumnSection" | "The height of the ." | | true | | "SubTaggedColumnSection" | "InsideDiameter" | "Length" | "ColumnSection" | "The inside diameter of the ." | | true | | "SwingCheckValve" | "InsulationThickness" | "Length" | "CheckValve" | "The insulation thickness of the ." | | true | | "SwingCheckValve" | "LowerLimitHeatTracingTemperature" | "Temperature" | "CheckValve" | "The temperature that a heat tracing system must ensure for the . " | | true | | "TaggedColumnSection" | "Height" | "Length" | "ColumnSection" | "The height of the ." | | true | | "TaggedColumnSection" | "InsideDiameter" | "Length" | "ColumnSection" | "The inside diameter of the ." | | true | | "Tank" | "CylinderLength" | "Length" | "Tank" | "The cylinder length of the ." | | true | | "Tank" | "NominalCapacity(Volume)" | "Volume" | "Vessel" | "The nominal volumetric capacity of the ." | | true | | "ThinFilmEvaporator" | "DesignHeatTransferArea" | "Area" | "HeatExchanger" | "The design heat transfer area of the ." | | true | | "ThinFilmEvaporator" | "DesignHeatTransferCoefficient" | "HeatTransferCoefficient" | "HeatExchanger" | "The design heat transfer coefficient of the ." | | true | | "ThinFilmEvaporator" | "DesignHeatFlowRate" | "Power" | "HeatExchanger" | "The heat flow rate for which the is designed." | | true | | "ThinFilmEvaporator" | "DesignPower" | "Power" | "ThinFilmEvaporator" | "The design power of the ." | | true | | "ThinFilmEvaporator" | "DesignShaftPower" | "Power" | "ThinFilmEvaporator" | "The design shaft power of the ." | | true | | "ThinFilmEvaporator" | "DesignRotationalSpeed" | "RotationalSpeed" | "ThinFilmEvaporator" | "The design rotational speed of the ." | | true | | "TubeBundle" | "TubeLength" | "Length" | "TubeBundle" | "The length of the tubes of the ." | | true | | "TurbineFlowMeter" | "InsulationThickness" | "Length" | "InlinePrimaryElement" | "The insulation thickness of the ." | | true | | "TurbineFlowMeter" | "LowerLimitHeatTracingTemperature" | "Temperature" | "InlinePrimaryElement" | "The temperature that a heat tracing system must ensure for the . " | | true | | "VariableAreaFlowMeter" | "InsulationThickness" | "Length" | "InlinePrimaryElement" | "The insulation thickness of the ." | | true | | "VariableAreaFlowMeter" | "LowerLimitHeatTracingTemperature" | "Temperature" | "InlinePrimaryElement" | "The temperature that a heat tracing system must ensure for the . " | | true | | "VentilationDevice" | "InsulationThickness" | "Length" | "PipeFitting" | "The insulation thickness of the ." | | true | | "VentilationDevice" | "LowerLimitHeatTracingTemperature" | "Temperature" | "PipeFitting" | "The temperature that a heat tracing system must ensure for the . " | | true | | "VenturiTube" | "InsulationThickness" | "Length" | "InlinePrimaryElement" | "The insulation thickness of the ." | | true | | "VenturiTube" | "LowerLimitHeatTracingTemperature" | "Temperature" | "InlinePrimaryElement" | "The temperature that a heat tracing system must ensure for the . " | | true | | "Vessel" | "NominalCapacity(Volume)" | "Volume" | "Vessel" | "The nominal volumetric capacity of the ." | | true | | "VolumetricFlowDetector" | "InsulationThickness" | "Length" | "InlinePrimaryElement" | "The insulation thickness of the ." | | true | | "VolumetricFlowDetector" | "LowerLimitHeatTracingTemperature" | "Temperature" | "InlinePrimaryElement" | "The temperature that a heat tracing system must ensure for the . " | | true | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------