--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | cls | attribute | decl_cls | description | rdl | is_proteus_generic_attribute | ========================================================================================================================================================================================================================================================================================================================================================================================================================================================================================================================================================================================================================================================= | "ActuatingFunction" | "ActuatingFunctionNumberAssignmentClass" | "ActuatingFunction" | "An identifier for the . It usually contains the identifier of the \\labeledref[class:]{ProcessInstrumentationFunction} that includes the (see \\labeledref[declaration:ProcessInstrumentationFunction:]{ProcessInstrumentationFunctionNumberAssignmentClass}). " | | true | | "ActuatingSystem" | "ActuatingSystemNumberAssignmentClass" | "ActuatingSystem" | "The number of the " | | true | | "ActuatingSystem" | "TypicalInformationAssignmentClass" | "ActuatingSystem" | "Typical information about the ." | | true | | "Agitator" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "Agitator" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "Agitator" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "Agitator" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "Agitator" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "AgitatorRotor" | "MaterialOfConstructionCodeAssignmentClass" | "AgitatorRotor" | "A code that gives the material of construction of the ." | | true | | "AgitatorRotor" | "RotorTypeAssignmentClass" | "AgitatorRotor" | "The rotor type of the ." | | true | | "AirCoolingSystem" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "AirCoolingSystem" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "AirCoolingSystem" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "AirCoolingSystem" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "AirCoolingSystem" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "AirEjector" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "AirEjector" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "AirEjector" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "AirEjector" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "AirEjector" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "AngleBallValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "AngleBallValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "AngleBallValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "AngleBallValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "AngleBallValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "AngleBallValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "AngleBallValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "AngleBallValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "AngleBallValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "AngleGlobeValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "AngleGlobeValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "AngleGlobeValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "AngleGlobeValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "AngleGlobeValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "AngleGlobeValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "AngleGlobeValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "AngleGlobeValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "AngleGlobeValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "AnglePlugValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "AnglePlugValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "AnglePlugValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "AnglePlugValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "AnglePlugValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "AnglePlugValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "AnglePlugValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "AnglePlugValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "AnglePlugValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "AngleValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "AngleValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "AngleValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "AngleValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "AngleValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "AngleValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "AngleValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "AngleValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "AngleValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "AreaIsa95" | "AreaIdentificationCodeAssignmentClass" | "AreaIsa95" | "The identification code of the ." | | true | | "AreaIsa95" | "AreaNameAssignmentClass" | "AreaIsa95" | "The name of the ." | | true | | "AxialCompressor" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "AxialCompressor" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "AxialCompressor" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "AxialCompressor" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "AxialCompressor" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "BallValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "BallValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "BallValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "BallValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "BallValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "BallValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "BallValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "BallValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "BallValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "BlindFlange" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "BlindFlange" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "BlindFlange" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "BlindFlange" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "BlindFlange" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "BlindFlange" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "BlindFlange" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "BlindFlange" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "BlindFlange" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "BreatherValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "BreatherValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "BreatherValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "BreatherValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "BreatherValve" | "FlowInPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow in side of ." | | true | | "BreatherValve" | "FlowOutPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow out side of ." | | true | | "BreatherValve" | "LocationRegistrationNumberAssignmentClass" | "SafetyValveOrFitting" | "The location registration number of the ." | | true | | "BreatherValve" | "PositionNumberAssignmentClass" | "SafetyValveOrFitting" | "The position number of the ." | | true | | "ButterflyValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "ButterflyValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "ButterflyValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "ButterflyValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "ButterflyValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "ButterflyValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "ButterflyValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "ButterflyValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "ButterflyValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "CentrifugalCompressor" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "CentrifugalCompressor" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "CentrifugalCompressor" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "CentrifugalCompressor" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "CentrifugalCompressor" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "CentrifugalPump" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "CentrifugalPump" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "CentrifugalPump" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "CentrifugalPump" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "CentrifugalPump" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "Chamber" | "ChamberDescriptionAssignmentClass" | "Chamber" | "The description of the ." | | true | | "Chamber" | "ChamberFunctionAssignmentClass" | "Chamber" | "The function of the ." | | true | | "Chamber" | "MaterialOfConstructionCodeAssignmentClass" | "Chamber" | "A code that gives the material of construction of the ." | | true | | "Chamber" | "NominalDiameterTypeRepresentationAssignmentClass" | "Chamber" | "A readable representation of the type of the nominal diameter of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "Chamber" | "SubTagNameAssignmentClass" | "Chamber" | "The sub tag name of the ." | | true | | "CheckValve" | "HeatTracingTypeAssignmentClass" | "CheckValve" | "The heat tracing type related to the , represented as a string. " | | true | | "CheckValve" | "InsulationTypeAssignmentClass" | "CheckValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "CheckValve" | "PipingClassCodeAssignmentClass" | "CheckValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "CheckValve" | "PipingComponentNameAssignmentClass" | "CheckValve" | "The piping component name of the ." | | true | | "CheckValve" | "PipingComponentNumberAssignmentClass" | "CheckValve" | "The piping component number of the ." | | true | | "CheckValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "CheckValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "CheckValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "CheckValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "ClampedFlangeCoupling" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "ClampedFlangeCoupling" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "ClampedFlangeCoupling" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "ClampedFlangeCoupling" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "ClampedFlangeCoupling" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "ClampedFlangeCoupling" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "ClampedFlangeCoupling" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "ClampedFlangeCoupling" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "ClampedFlangeCoupling" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "ColumnPackingsArrangement" | "MaterialOfConstructionCodeAssignmentClass" | "ColumnPackingsArrangement" | "A code that gives the material of construction of the ." | | true | | "ColumnPackingsArrangement" | "PackingTypeAssignmentClass" | "ColumnPackingsArrangement" | "The type of the packings in the ." | | true | | "ColumnTraysArrangement" | "MaterialOfConstructionCodeAssignmentClass" | "ColumnTraysArrangement" | "A code that gives the material of construction of the ." | | true | | "ColumnTraysArrangement" | "TrayTypeAssignmentClass" | "ColumnTraysArrangement" | "The type of the trays in the ." | | true | | "Compensator" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "Compensator" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Compensator" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "Compensator" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "Compensator" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "Compensator" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "Compensator" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Compensator" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "Compensator" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "Compressor" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "Compressor" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "Compressor" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "Compressor" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "Compressor" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "ConicalStrainer" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "ConicalStrainer" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "ConicalStrainer" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "ConicalStrainer" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "ConicalStrainer" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "ConicalStrainer" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "ConicalStrainer" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "ConicalStrainer" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "ConicalStrainer" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "ControlledActuator" | "DeviceTypeNameAssignmentClass" | "ControlledActuator" | "The device type of the ." | | true | | "ControlledActuator" | "FailActionRepresentationAssignmentClass" | "ControlledActuator" | "A readable representation of the fail action of the . This attribute should also be referenced in the graphics if applicable." | | true | | "ControlledActuator" | "SubTagNameAssignmentClass" | "ControlledActuator" | "The sub tag name of the ." | | true | | "Displacer" | "MaterialOfConstructionCodeAssignmentClass" | "Displacer" | "A code that gives the material of construction of the ." | | true | | "Displacer" | "StageIdentifierAssignmentClass" | "Displacer" | "The stage identfifier of of the ." | | true | | "EjectorPump" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "EjectorPump" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "EjectorPump" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "EjectorPump" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "EjectorPump" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "ElectricHeater" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "ElectricHeater" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "ElectricHeater" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "ElectricHeater" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "ElectricHeater" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "ElectromagneticFlowMeter" | "HeatTracingTypeAssignmentClass" | "InlinePrimaryElement" | "The heat tracing type related to the , represented as a string. " | | true | | "ElectromagneticFlowMeter" | "InsulationTypeAssignmentClass" | "InlinePrimaryElement" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "ElectromagneticFlowMeter" | "PipingComponentNameAssignmentClass" | "InlinePrimaryElement" | "The piping component name of the ." | | true | | "ElectromagneticFlowMeter" | "PipingComponentNumberAssignmentClass" | "InlinePrimaryElement" | "The piping component number of the ." | | true | | "ElectromagneticFlowMeter" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "ElectromagneticFlowMeter" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "ElectromagneticFlowMeter" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "ElectromagneticFlowMeter" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "Equipment" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "Equipment" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "Equipment" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "Equipment" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "Equipment" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "Filter" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "Filter" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "Filter" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "Filter" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "Filter" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "FilterUnit" | "MaterialOfConstructionCodeAssignmentClass" | "FilterUnit" | "A code that gives the material of construction of the ." | | true | | "FlameArrestor" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "FlameArrestor" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "FlameArrestor" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "FlameArrestor" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "FlameArrestor" | "FlowInPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow in side of ." | | true | | "FlameArrestor" | "FlowOutPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow out side of ." | | true | | "FlameArrestor" | "LocationRegistrationNumberAssignmentClass" | "SafetyValveOrFitting" | "The location registration number of the ." | | true | | "FlameArrestor" | "PositionNumberAssignmentClass" | "SafetyValveOrFitting" | "The position number of the ." | | true | | "Flange" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "Flange" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Flange" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "Flange" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "Flange" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "Flange" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "Flange" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Flange" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "Flange" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "FlangedConnection" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "FlangedConnection" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "FlangedConnection" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "FlangedConnection" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "FlangedConnection" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "FlangedConnection" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "FlangedConnection" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "FlangedConnection" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "FlangedConnection" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "FlowDetector" | "HeatTracingTypeAssignmentClass" | "InlinePrimaryElement" | "The heat tracing type related to the , represented as a string. " | | true | | "FlowDetector" | "InsulationTypeAssignmentClass" | "InlinePrimaryElement" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "FlowDetector" | "PipingComponentNameAssignmentClass" | "InlinePrimaryElement" | "The piping component name of the ." | | true | | "FlowDetector" | "PipingComponentNumberAssignmentClass" | "InlinePrimaryElement" | "The piping component number of the ." | | true | | "FlowDetector" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "FlowDetector" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "FlowDetector" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "FlowDetector" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "FlowNozzle" | "HeatTracingTypeAssignmentClass" | "InlinePrimaryElement" | "The heat tracing type related to the , represented as a string. " | | true | | "FlowNozzle" | "InsulationTypeAssignmentClass" | "InlinePrimaryElement" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "FlowNozzle" | "PipingComponentNameAssignmentClass" | "InlinePrimaryElement" | "The piping component name of the ." | | true | | "FlowNozzle" | "PipingComponentNumberAssignmentClass" | "InlinePrimaryElement" | "The piping component number of the ." | | true | | "FlowNozzle" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "FlowNozzle" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "FlowNozzle" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "FlowNozzle" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "Funnel" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "Funnel" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Funnel" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "Funnel" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "Funnel" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "Funnel" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "Funnel" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Funnel" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "Funnel" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "GasFilter" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "GasFilter" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "GasFilter" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "GasFilter" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "GasFilter" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "GateValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "GateValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "GateValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "GateValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "GateValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "GateValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "GateValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "GateValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "GateValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "GlobeCheckValve" | "HeatTracingTypeAssignmentClass" | "CheckValve" | "The heat tracing type related to the , represented as a string. " | | true | | "GlobeCheckValve" | "InsulationTypeAssignmentClass" | "CheckValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "GlobeCheckValve" | "PipingClassCodeAssignmentClass" | "CheckValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "GlobeCheckValve" | "PipingComponentNameAssignmentClass" | "CheckValve" | "The piping component name of the ." | | true | | "GlobeCheckValve" | "PipingComponentNumberAssignmentClass" | "CheckValve" | "The piping component number of the ." | | true | | "GlobeCheckValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "GlobeCheckValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "GlobeCheckValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "GlobeCheckValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "GlobeValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "GlobeValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "GlobeValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "GlobeValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "GlobeValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "GlobeValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "GlobeValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "GlobeValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "GlobeValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "HeatExchanger" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "HeatExchanger" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "HeatExchanger" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "HeatExchanger" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "HeatExchanger" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "HeatExchangerRotor" | "MaterialOfConstructionCodeAssignmentClass" | "HeatExchangerRotor" | "A code that gives the material of construction of the ." | | true | | "Hose" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "Hose" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Hose" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "Hose" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "Hose" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "Hose" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "Hose" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Hose" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "Hose" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "IlluminatedSightGlass" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "IlluminatedSightGlass" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "IlluminatedSightGlass" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "IlluminatedSightGlass" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "IlluminatedSightGlass" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "IlluminatedSightGlass" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "IlluminatedSightGlass" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "IlluminatedSightGlass" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "IlluminatedSightGlass" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "Impeller" | "MaterialOfConstructionCodeAssignmentClass" | "Impeller" | "A code that gives the material of construction of the ." | | true | | "Impeller" | "StageIdentifierAssignmentClass" | "Impeller" | "The stage identfifier of of the ." | | true | | "InLineMixer" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "InLineMixer" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "InLineMixer" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "InLineMixer" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "InLineMixer" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "InLineMixer" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "InLineMixer" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "InLineMixer" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "InLineMixer" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "IndustrialComplexIso10209-2012" | "IndustrialComplexIdentificationCodeAssignmentClass" | "IndustrialComplexIso10209-2012" | "The identification code of the ." | | true | | "IndustrialComplexIso10209-2012" | "IndustrialComplexNameAssignmentClass" | "IndustrialComplexIso10209-2012" | "The name of the ." | | true | | "InlinePrimaryElement" | "HeatTracingTypeAssignmentClass" | "InlinePrimaryElement" | "The heat tracing type related to the , represented as a string. " | | true | | "InlinePrimaryElement" | "InsulationTypeAssignmentClass" | "InlinePrimaryElement" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "InlinePrimaryElement" | "PipingComponentNameAssignmentClass" | "InlinePrimaryElement" | "The piping component name of the ." | | true | | "InlinePrimaryElement" | "PipingComponentNumberAssignmentClass" | "InlinePrimaryElement" | "The piping component number of the ." | | true | | "InlinePrimaryElement" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "InlinePrimaryElement" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "InlinePrimaryElement" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "InlinePrimaryElement" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "InlinePrimaryElementReference" | "SubTagNameAssignmentClass" | "PrimaryElement" | "The sub tag name of the ." | | true | | "InstrumentationLoopFunction" | "InstrumentationLoopFunctionNumberAssignmentClass" | "InstrumentationLoopFunction" | "The identification number of the ." | | true | | "Isa95Enterprise" | "EnterpriseIdentificationCodeAssignmentClass" | "Isa95Enterprise" | "The identification code of the ." | | true | | "Isa95Enterprise" | "EnterpriseNameAssignmentClass" | "Isa95Enterprise" | "The name of the ." | | true | | "Kneader" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "Kneader" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "Kneader" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "Kneader" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "Kneader" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "LineBlind" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "LineBlind" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "LineBlind" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "LineBlind" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "LineBlind" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "LineBlind" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "LineBlind" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "LineBlind" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "LineBlind" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "LiquidFilter" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "LiquidFilter" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "LiquidFilter" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "LiquidFilter" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "LiquidFilter" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "MeasuringLineFunction" | "SignalPointNumberAssignmentClass" | "SignalConveyingFunction" | "The signal point number of the . Typical values are 1 to 6." | | true | | "MeasuringLineFunction" | "SignalProcessControlFunctionsAssignmentClass" | "SignalConveyingFunction" | "The process control functions of the . Values are combinations of characters." | | true | | "MetaData" | "ApprovalDateRepresentationAssignmentClass" | "MetaData" | "A representation of the approval date of the drawing." | | true | | "MetaData" | "ApprovalDescriptionAssignmentClass" | "MetaData" | "A description of the approval of the drawing." | | true | | "MetaData" | "ApproverNameAssignmentClass" | "MetaData" | "The name of the approver of the drawing." | | true | | "MetaData" | "ArchiveNumberAssignmentClass" | "MetaData" | "The archive number of the drawing." | | true | | "MetaData" | "AreaIsa95NameAssignmentClass" | "MetaData" | "The name of the related area according to ISA-95." | | true | | "MetaData" | "BlockNameAssignmentClass" | "MetaData" | "The name of the related block." | | true | | "MetaData" | "BlockNumberAssignmentClass" | "MetaData" | "The number of the related block." | | true | | "MetaData" | "CheckerNameAssignmentClass" | "MetaData" | "The name of the checker of the drawing." | | true | | "MetaData" | "CompanyNameAssignmentClass" | "MetaData" | "The name of the company." | | true | | "MetaData" | "CompanyNumberAssignmentClass" | "MetaData" | "The number of the company." | | true | | "MetaData" | "CreationDateRepresentationAssignmentClass" | "MetaData" | "A representation of the creation date of the drawing." | | true | | "MetaData" | "CreatorNameAssignmentClass" | "MetaData" | "The name of the creator of the drawing." | | true | | "MetaData" | "DesignerNameAssignmentClass" | "MetaData" | "The name of the designer of the drawing." | | true | | "MetaData" | "DrafterNameAssignmentClass" | "MetaData" | "The name of the drafter of the drawing." | | true | | "MetaData" | "DrawingNameAssignmentClass" | "MetaData" | "The drawing name." | | true | | "MetaData" | "DrawingNumberAssignmentClass" | "MetaData" | "The drawing number." | | true | | "MetaData" | "DrawingSubTitleAssignmentClass" | "MetaData" | "The sub-title of the drawing." | | true | | "MetaData" | "FileNameAssignmentClass" | "MetaData" | "The name of the drawing file." | | true | | "MetaData" | "LastModificationDateRepresentationAssignmentClass" | "MetaData" | "A representation of the last modification date of the drawing." | | true | | "MetaData" | "LocationNameAssignmentClass" | "MetaData" | "The location name." | | true | | "MetaData" | "ProcessCellIsa95NameAssignmentClass" | "MetaData" | "The name of the related process cell according to ISA-95." | | true | | "MetaData" | "ProcessCellIsa95NumberAssignmentClass" | "MetaData" | "The number of the related process cell according to ISA-95." | | true | | "MetaData" | "ProjectNameAssignmentClass" | "MetaData" | "The name of the related project." | | true | | "MetaData" | "ProjectNumberAssignmentClass" | "MetaData" | "The number of the related project." | | true | | "MetaData" | "ProjectRangeNumberAssignmentClass" | "MetaData" | "The range number of he related project." | | true | | "MetaData" | "ReplacedDrawingAssignmentClass" | "MetaData" | "The drawing replaced by this drawing." | | true | | "MetaData" | "ResponsibleDepartmentNameAssignmentClass" | "MetaData" | "The name of the department responsible for the drawing." | | true | | "MetaData" | "RevisionNumberAssignmentClass" | "MetaData" | "The revision number of the drawing." | | true | | "MetaData" | "SheetFormatAssignmentClass" | "MetaData" | "The sheet format." | | true | | "MetaData" | "SheetNumberAssignmentClass" | "MetaData" | "The sheet number of the drawing." | | true | | "MetaData" | "SiteIsa95NameAssignmentClass" | "MetaData" | "The name of the related site according to ISA-95." | | true | | "MetaData" | "SubProjectNameAssignmentClass" | "MetaData" | "The name of the related sub-project." | | true | | "MetaData" | "SubProjectNumberAssignmentClass" | "MetaData" | "The number of the related sub-project." | | true | | "MetaData" | "UnitIsa95NameAssignmentClass" | "MetaData" | "The name of the related unit according to ISA-95." | | true | | "MetaData" | "UnitIsa95NumberAssignmentClass" | "MetaData" | "The number of the related unit according to ISA-95." | | true | | "Mixer" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "Mixer" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "Mixer" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "Mixer" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "Mixer" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "MixingElementAssembly" | "MaterialOfConstructionCodeAssignmentClass" | "MixingElementAssembly" | "A code that gives the material of construction of the ." | | true | | "NeedleValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "NeedleValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "NeedleValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "NeedleValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "NeedleValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "NeedleValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "NeedleValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "NeedleValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "NeedleValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "Nozzle" | "NominalPressureNumericalValueRepresentationAssignmentClass" | "Nozzle" | "A readable representation of the numerical value of the nominal pressure. The purpose of this value is to give a textual representation of the nominal pressure to be used in the graphics of a PID." | | true | | "Nozzle" | "NominalPressureRepresentationAssignmentClass" | "Nozzle" | "A readable representation of the nominal pressure. The purpose of this value is to give a textual representation of the nominal pressure to be used in the graphics of a PID." | | true | | "Nozzle" | "NominalPressureTypeRepresentationAssignmentClass" | "Nozzle" | "A readable representation of the type of the nominal pressure. The purpose of this value is to give a textual representation of the nominal pressure to be used in the graphics of a PID." | | true | | "Nozzle" | "SubTagNameAssignmentClass" | "Nozzle" | "The sub tag name of the ." | | true | | "OfflinePrimaryElement" | "ConnectionNominalDiameterNumericalValueRepresentationAssignmentClass" | "OfflinePrimaryElement" | "A readable representation of the numerical value of the nominal diameter at the device connection of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "OfflinePrimaryElement" | "ConnectionNominalDiameterRepresentationAssignmentClass" | "OfflinePrimaryElement" | "A readable representation of the nominal diameter at the device connection of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "OfflinePrimaryElement" | "ConnectionNominalDiameterTypeRepresentationAssignmentClass" | "OfflinePrimaryElement" | "A readable representation of the type of the nominal diameter at the device connection of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "OfflinePrimaryElement" | "FluidCodeAssignmentClass" | "OfflinePrimaryElement" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "OfflinePrimaryElement" | "HeatTracingTypeAssignmentClass" | "OfflinePrimaryElement" | "The heat tracing type related to the , represented as a string. " | | true | | "OfflinePrimaryElement" | "InsulationTypeAssignmentClass" | "OfflinePrimaryElement" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "OfflinePrimaryElement" | "LocationNominalDiameterNumericalValueRepresentationAssignmentClass" | "OfflinePrimaryElement" | "A readable representation of the numerical value of the nominal diameter at the location of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "OfflinePrimaryElement" | "LocationNominalDiameterRepresentationAssignmentClass" | "OfflinePrimaryElement" | "A readable representation of the nominal diameter at the location of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "OfflinePrimaryElement" | "LocationNominalDiameterTypeRepresentationAssignmentClass" | "OfflinePrimaryElement" | "A readable representation of the type of the nominal diameter at the location of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "OfflinePrimaryElement" | "SubTagNameAssignmentClass" | "PrimaryElement" | "The sub tag name of the ." | | true | | "OrificePlate" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "OrificePlate" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "OrificePlate" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "OrificePlate" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "OrificePlate" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "OrificePlate" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "OrificePlate" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "OrificePlate" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "OrificePlate" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "Penetration" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "Penetration" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Penetration" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "Penetration" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "Penetration" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "Penetration" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "Penetration" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Penetration" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "Penetration" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "PipeCoupling" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "PipeCoupling" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeCoupling" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeCoupling" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "PipeCoupling" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "PipeCoupling" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "PipeCoupling" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeCoupling" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "PipeCoupling" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "PipeFitting" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "PipeFitting" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeFitting" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeFitting" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "PipeFitting" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "PipeFitting" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "PipeFitting" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeFitting" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "PipeFitting" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "PipeFlangeSpacer" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "PipeFlangeSpacer" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeFlangeSpacer" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeFlangeSpacer" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "PipeFlangeSpacer" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "PipeFlangeSpacer" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "PipeFlangeSpacer" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeFlangeSpacer" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "PipeFlangeSpacer" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "PipeFlangeSpade" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "PipeFlangeSpade" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeFlangeSpade" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeFlangeSpade" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "PipeFlangeSpade" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "PipeFlangeSpade" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "PipeFlangeSpade" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeFlangeSpade" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "PipeFlangeSpade" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "PipeReducer" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "PipeReducer" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeReducer" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeReducer" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "PipeReducer" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "PipeReducer" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "PipeReducer" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeReducer" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "PipeReducer" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "PipeTee" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "PipeTee" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeTee" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeTee" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "PipeTee" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "PipeTee" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "PipeTee" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipeTee" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "PipeTee" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "PipingComponent" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "PipingComponent" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipingComponent" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "PipingComponent" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "PipingNetworkSegment" | "BasfLineClassAssignmentClass" | "PipingNetworkSegment" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "PipingNetworkSegment" | "ColorCodeAssignmentClass" | "PipingNetworkSegment" | "The color code of the , represented as a string." | | true | | "PipingNetworkSegment" | "FluidCodeAssignmentClass" | "PipingNetworkSegment" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipingNetworkSegment" | "HeatTracingTypeAssignmentClass" | "PipingNetworkSegment" | "The heat tracing type related to the , represented as a string. " | | true | | "PipingNetworkSegment" | "InsulationTypeAssignmentClass" | "PipingNetworkSegment" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipingNetworkSegment" | "NominalDiameterNumericalValueRepresentationAssignmentClass" | "PipingNetworkSegment" | "A readable representation of the numerical value of the nominal diameter of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "PipingNetworkSegment" | "NominalDiameterRepresentationAssignmentClass" | "PipingNetworkSegment" | "A readable representation of the nominal diameter of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "PipingNetworkSegment" | "NominalDiameterTypeRepresentationAssignmentClass" | "PipingNetworkSegment" | "A readable representation of the type of the nominal diameter of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "PipingNetworkSegment" | "PipingClassCodeAssignmentClass" | "PipingNetworkSegment" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipingNetworkSegment" | "PressureTestCircuitNumberAssignmentClass" | "PipingNetworkSegment" | "The number of the pressure test circuit of the ." | | true | | "PipingNetworkSegment" | "SegmentNumberAssignmentClass" | "PipingNetworkSegment" | "The segment number of a . Values are typically (but not necessarily) string representations of numbers with a prefix." | | true | | "PipingNetworkSystem" | "FluidCodeAssignmentClass" | "PipingNetworkSystem" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipingNetworkSystem" | "HeatTracingTypeAssignmentClass" | "PipingNetworkSystem" | "The heat tracing type related to the , represented as a string. " | | true | | "PipingNetworkSystem" | "InsulationTypeAssignmentClass" | "PipingNetworkSystem" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipingNetworkSystem" | "JacketLineNumberAssignmentClass" | "PipingNetworkSystem" | "The line number of the \\name{PipingNetworkSystem} that is the jacket of this ." | | true | | "PipingNetworkSystem" | "JacketedLineNumberAssignmentClass" | "PipingNetworkSystem" | "The line number of the \\name{PipingNetworkSystem} for which this is the jacket." | | true | | "PipingNetworkSystem" | "LineNumberAssignmentClass" | "PipingNetworkSystem" | "The line number of a . Values are typically (but not necessarily) string representations of numbers." | | true | | "PipingNetworkSystem" | "NominalDiameterNumericalValueRepresentationAssignmentClass" | "PipingNetworkSystem" | "A readable representation of the numerical value of the nominal diameter of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "PipingNetworkSystem" | "NominalDiameterRepresentationAssignmentClass" | "PipingNetworkSystem" | "A readable representation of the nominal diameter of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "PipingNetworkSystem" | "NominalDiameterTypeRepresentationAssignmentClass" | "PipingNetworkSystem" | "A readable representation of the type of the nominal diameter of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "PipingNetworkSystem" | "PipingClassCodeAssignmentClass" | "PipingNetworkSystem" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "PipingNetworkSystem" | "PipingNetworkSystemGroupNumberAssignmentClass" | "PipingNetworkSystem" | "The number of the piping network system group of the , represented as a string." | | true | | "PipingNode" | "NominalDiameterNumericalValueRepresentationAssignmentClass" | "PipingNode" | "A readable representation of the numerical value of the nominal diameter of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "PipingNode" | "NominalDiameterRepresentationAssignmentClass" | "PipingNode" | "A readable representation of the nominal diameter of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "PipingNode" | "NominalDiameterTypeRepresentationAssignmentClass" | "PipingNode" | "A readable representation of the type of the nominal diameter of the . The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "PlantSectionIso10209-2012" | "PlantSectionIdentificationCodeAssignmentClass" | "PlantSectionIso10209-2012" | "The identification code of the ." | | true | | "PlantSectionIso10209-2012" | "PlantSectionNameAssignmentClass" | "PlantSectionIso10209-2012" | "The name of the ." | | true | | "PlantSystem" | "PlantSystemIdentificationCodeAssignmentClass" | "PlantSystem" | "The identification code of the ." | | true | | "PlantSystem" | "PlantSystemNameAssignmentClass" | "PlantSystem" | "The name of the ." | | true | | "PlantTrain" | "PlantTrainIdentificationCodeAssignmentClass" | "PlantTrain" | "The identification code of the ." | | true | | "PlantTrain" | "PlantTrainNameAssignmentClass" | "PlantTrain" | "The name of the ." | | true | | "PlateAndShellHeatExchanger" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "PlateAndShellHeatExchanger" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "PlateAndShellHeatExchanger" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "PlateAndShellHeatExchanger" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "PlateAndShellHeatExchanger" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "PlugValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "PlugValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PlugValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "PlugValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "PlugValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "PlugValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PlugValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "PlugValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "PlugValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "Positioner" | "DeviceTypeNameAssignmentClass" | "Positioner" | "The device type of the ." | | true | | "Positioner" | "SubTagNameAssignmentClass" | "Positioner" | "The sub tag name of the ." | | true | | "PositiveDisplacementFlowMeter" | "HeatTracingTypeAssignmentClass" | "InlinePrimaryElement" | "The heat tracing type related to the , represented as a string. " | | true | | "PositiveDisplacementFlowMeter" | "InsulationTypeAssignmentClass" | "InlinePrimaryElement" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PositiveDisplacementFlowMeter" | "PipingComponentNameAssignmentClass" | "InlinePrimaryElement" | "The piping component name of the ." | | true | | "PositiveDisplacementFlowMeter" | "PipingComponentNumberAssignmentClass" | "InlinePrimaryElement" | "The piping component number of the ." | | true | | "PositiveDisplacementFlowMeter" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "PositiveDisplacementFlowMeter" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "PositiveDisplacementFlowMeter" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "PositiveDisplacementFlowMeter" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "PressureVessel" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "PressureVessel" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "PressureVessel" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "PressureVessel" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "PressureVessel" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "PrimaryElement" | "SubTagNameAssignmentClass" | "PrimaryElement" | "The sub tag name of the ." | | true | | "ProcessColumn" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "ProcessColumn" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "ProcessColumn" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "ProcessColumn" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "ProcessColumn" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "ProcessControlFunction" | "DeviceInformationAssignmentClass" | "ProcessInstrumentationFunction" | "Device information the , e.g., for a detector." | | true | | "ProcessControlFunction" | "PanelIdentificationCodeAssignmentClass" | "ProcessInstrumentationFunction" | "The panel identification code of the ." | | true | | "ProcessControlFunction" | "ProcessInstrumentationFunctionCategoryAssignmentClass" | "ProcessInstrumentationFunction" | "The function category of the . The value is a string, typically one or two letters. Recent standards for PIDs normally enforce a single letter from a fixed list. However, there are no formal DEXPI restrictions for valid strings." | | true | | "ProcessControlFunction" | "ProcessInstrumentationFunctionModifierAssignmentClass" | "ProcessInstrumentationFunction" | "The modifier of the . The value is a string, typically a single letter, e.g., D for difference. So far, there are no formal DEXPI restrictions for valid strings." | | true | | "ProcessControlFunction" | "ProcessInstrumentationFunctionNumberAssignmentClass" | "ProcessInstrumentationFunction" | "A unique identifier for the . If the is part of a \\labeledref[class:]{InstrumentationLoopFunction}, the identifier of the usually contains the identifier of the \\labeledref[class:]{InstrumentationLoopFunction} (see \\labeledref[declaration:InstrumentationLoopFunction:]{InstrumentationLoopFunctionNumberAssignmentClass}). " | | true | | "ProcessControlFunction" | "ProcessInstrumentationFunctionsAssignmentClass" | "ProcessInstrumentationFunction" | "Additional functions of the (i.e., in addition to the function category, see \\labeledref[declaration:ProcessInstrumentationFunction:]{ProcessInstrumentationFunctionCategoryAssignmentClass}). " | | true | | "ProcessControlFunction" | "SafetyRelevanceClassAssignmentClass" | "ProcessInstrumentationFunction" | "The safety relevance class the ." | | true | | "ProcessControlFunction" | "TypicalInformationAssignmentClass" | "ProcessInstrumentationFunction" | "Typical information about the ." | | true | | "ProcessControlFunction" | "VendorCompanyNameAssignmentClass" | "ProcessInstrumentationFunction" | "The vendor company name the ." | | true | | "ProcessControlFunction" | "VotingSystemRepresentationAssignmentClass" | "ProcessInstrumentationFunction" | "A representation of the voting system of the ." | | true | | "ProcessInstrumentationFunction" | "DeviceInformationAssignmentClass" | "ProcessInstrumentationFunction" | "Device information the , e.g., for a detector." | | true | | "ProcessInstrumentationFunction" | "PanelIdentificationCodeAssignmentClass" | "ProcessInstrumentationFunction" | "The panel identification code of the ." | | true | | "ProcessInstrumentationFunction" | "ProcessInstrumentationFunctionCategoryAssignmentClass" | "ProcessInstrumentationFunction" | "The function category of the . The value is a string, typically one or two letters. Recent standards for PIDs normally enforce a single letter from a fixed list. However, there are no formal DEXPI restrictions for valid strings." | | true | | "ProcessInstrumentationFunction" | "ProcessInstrumentationFunctionModifierAssignmentClass" | "ProcessInstrumentationFunction" | "The modifier of the . The value is a string, typically a single letter, e.g., D for difference. So far, there are no formal DEXPI restrictions for valid strings." | | true | | "ProcessInstrumentationFunction" | "ProcessInstrumentationFunctionNumberAssignmentClass" | "ProcessInstrumentationFunction" | "A unique identifier for the . If the is part of a \\labeledref[class:]{InstrumentationLoopFunction}, the identifier of the usually contains the identifier of the \\labeledref[class:]{InstrumentationLoopFunction} (see \\labeledref[declaration:InstrumentationLoopFunction:]{InstrumentationLoopFunctionNumberAssignmentClass}). " | | true | | "ProcessInstrumentationFunction" | "ProcessInstrumentationFunctionsAssignmentClass" | "ProcessInstrumentationFunction" | "Additional functions of the (i.e., in addition to the function category, see \\labeledref[declaration:ProcessInstrumentationFunction:]{ProcessInstrumentationFunctionCategoryAssignmentClass}). " | | true | | "ProcessInstrumentationFunction" | "SafetyRelevanceClassAssignmentClass" | "ProcessInstrumentationFunction" | "The safety relevance class the ." | | true | | "ProcessInstrumentationFunction" | "TypicalInformationAssignmentClass" | "ProcessInstrumentationFunction" | "Typical information about the ." | | true | | "ProcessInstrumentationFunction" | "VendorCompanyNameAssignmentClass" | "ProcessInstrumentationFunction" | "The vendor company name the ." | | true | | "ProcessInstrumentationFunction" | "VotingSystemRepresentationAssignmentClass" | "ProcessInstrumentationFunction" | "A representation of the voting system of the ." | | true | | "ProcessPlant" | "ProcessPlantIdentificationCodeAssignmentClass" | "ProcessPlant" | "The identification code of the ." | | true | | "ProcessPlant" | "ProcessPlantNameAssignmentClass" | "ProcessPlant" | "The name of the ." | | true | | "ProcessSignalGeneratingFunction" | "ProcessSignalGeneratingFunctionNumberAssignmentClass" | "ProcessSignalGeneratingFunction" | "An identifier for the . It usually contains the identifier of the \\labeledref[class:]{ProcessInstrumentationFunction} that includes the (see \\labeledref[declaration:ProcessInstrumentationFunction:]{ProcessInstrumentationFunctionNumberAssignmentClass}). " | | true | | "ProcessSignalGeneratingFunction" | "SensorTypeAssignmentClass" | "ProcessSignalGeneratingFunction" | "The sensor type of the ." | | true | | "ProcessSignalGeneratingSystem" | "ProcessSignalGeneratingSystemNumberAssignmentClass" | "ProcessSignalGeneratingSystem" | "The number of the " | | true | | "ProcessSignalGeneratingSystem" | "TypicalInformationAssignmentClass" | "ProcessSignalGeneratingSystem" | "Typical information about the ." | | true | | "Pump" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "Pump" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "Pump" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "Pump" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "Pump" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "ReciprocatingCompressor" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "ReciprocatingCompressor" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "ReciprocatingCompressor" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "ReciprocatingCompressor" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "ReciprocatingCompressor" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "ReciprocatingPump" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "ReciprocatingPump" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "ReciprocatingPump" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "ReciprocatingPump" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "ReciprocatingPump" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "RotaryCompressor" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "RotaryCompressor" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "RotaryCompressor" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "RotaryCompressor" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "RotaryCompressor" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "RotaryMixer" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "RotaryMixer" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "RotaryMixer" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "RotaryMixer" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "RotaryMixer" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "RotaryPump" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "RotaryPump" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "RotaryPump" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "RotaryPump" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "RotaryPump" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "RuptureDisc" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "RuptureDisc" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "RuptureDisc" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "RuptureDisc" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "RuptureDisc" | "FlowInPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow in side of ." | | true | | "RuptureDisc" | "FlowOutPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow out side of ." | | true | | "RuptureDisc" | "LocationRegistrationNumberAssignmentClass" | "SafetyValveOrFitting" | "The location registration number of the ." | | true | | "RuptureDisc" | "PositionNumberAssignmentClass" | "SafetyValveOrFitting" | "The position number of the ." | | true | | "SafetyValveOrFitting" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "SafetyValveOrFitting" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "SafetyValveOrFitting" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "SafetyValveOrFitting" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "SafetyValveOrFitting" | "FlowInPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow in side of ." | | true | | "SafetyValveOrFitting" | "FlowOutPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow out side of ." | | true | | "SafetyValveOrFitting" | "LocationRegistrationNumberAssignmentClass" | "SafetyValveOrFitting" | "The location registration number of the ." | | true | | "SafetyValveOrFitting" | "PositionNumberAssignmentClass" | "SafetyValveOrFitting" | "The position number of the ." | | true | | "ShellAndTubeHeatExchanger" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "ShellAndTubeHeatExchanger" | "TemaStandardTypeAssignmentClass" | "ShellAndTubeHeatExchanger" | "The type of the according to the Tubular Exchanger Manufacturers Association, Inc. (TEMA, \\url{http://www.tema.org}). This is a three-letter code." | | true | | "ShellAndTubeHeatExchanger" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "ShellAndTubeHeatExchanger" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "ShellAndTubeHeatExchanger" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "ShellAndTubeHeatExchanger" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "ShutOffValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "ShutOffValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "ShutOffValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "ShutOffValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "ShutOffValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "ShutOffValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "ShutOffValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "ShutOffValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "ShutOffValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "ShutOffValveReference" | "SubTagNameAssignmentClass" | "ShutOffValveReference" | "The sub tag name of the ." | | true | | "SightGlass" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "SightGlass" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "SightGlass" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "SightGlass" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "SightGlass" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "SightGlass" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "SightGlass" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "SightGlass" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "SightGlass" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "SignalConveyingFunction" | "SignalPointNumberAssignmentClass" | "SignalConveyingFunction" | "The signal point number of the . Typical values are 1 to 6." | | true | | "SignalConveyingFunction" | "SignalProcessControlFunctionsAssignmentClass" | "SignalConveyingFunction" | "The process control functions of the . Values are combinations of characters." | | true | | "SignalLineFunction" | "SignalPointNumberAssignmentClass" | "SignalConveyingFunction" | "The signal point number of the . Typical values are 1 to 6." | | true | | "SignalLineFunction" | "SignalProcessControlFunctionsAssignmentClass" | "SignalConveyingFunction" | "The process control functions of the . Values are combinations of characters." | | true | | "Silencer" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "Silencer" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Silencer" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "Silencer" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "Silencer" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "Silencer" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "Silencer" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Silencer" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "Silencer" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "Silo" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "Silo" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "Silo" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "Silo" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "Silo" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "SiteIsa95" | "SiteIdentificationCodeAssignmentClass" | "SiteIsa95" | "The identification code of the ." | | true | | "SiteIsa95" | "SiteNameAssignmentClass" | "SiteIsa95" | "The name of the ." | | true | | "SpecialCompressor" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "SpecialCompressor" | "TypeNameAssignmentClass" | "SpecialCompressor" | "The name of the type of the ." | | true | | "SpecialCompressor" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "SpecialCompressor" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "SpecialCompressor" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "SpecialCompressor" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "SpecialPump" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "SpecialPump" | "TypeNameAssignmentClass" | "SpecialPump" | "The name of the type of the ." | | true | | "SpecialPump" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "SpecialPump" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "SpecialPump" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "SpecialPump" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "SpecialVessel" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "SpecialVessel" | "TypeNameAssignmentClass" | "SpecialVessel" | "The name of the type of the ." | | true | | "SpecialVessel" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "SpecialVessel" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "SpecialVessel" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "SpecialVessel" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "SpiralHeatExchanger" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "SpiralHeatExchanger" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "SpiralHeatExchanger" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "SpiralHeatExchanger" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "SpiralHeatExchanger" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "SpringLoadedAngleGlobeSafetyValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "SpringLoadedAngleGlobeSafetyValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "SpringLoadedAngleGlobeSafetyValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "SpringLoadedAngleGlobeSafetyValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "SpringLoadedAngleGlobeSafetyValve" | "FlowInPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow in side of ." | | true | | "SpringLoadedAngleGlobeSafetyValve" | "FlowOutPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow out side of ." | | true | | "SpringLoadedAngleGlobeSafetyValve" | "LocationRegistrationNumberAssignmentClass" | "SafetyValveOrFitting" | "The location registration number of the ." | | true | | "SpringLoadedAngleGlobeSafetyValve" | "PositionNumberAssignmentClass" | "SafetyValveOrFitting" | "The position number of the ." | | true | | "SpringLoadedGlobeSafetyValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "SpringLoadedGlobeSafetyValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "SpringLoadedGlobeSafetyValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "SpringLoadedGlobeSafetyValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "SpringLoadedGlobeSafetyValve" | "FlowInPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow in side of ." | | true | | "SpringLoadedGlobeSafetyValve" | "FlowOutPipingClassCodeAssignmentClass" | "SafetyValveOrFitting" | "The code of the piping class at the flow out side of ." | | true | | "SpringLoadedGlobeSafetyValve" | "LocationRegistrationNumberAssignmentClass" | "SafetyValveOrFitting" | "The location registration number of the ." | | true | | "SpringLoadedGlobeSafetyValve" | "PositionNumberAssignmentClass" | "SafetyValveOrFitting" | "The position number of the ." | | true | | "StaticMixer" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "StaticMixer" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "StaticMixer" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "StaticMixer" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "StaticMixer" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "SteamTrap" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "SteamTrap" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "SteamTrap" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "SteamTrap" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "SteamTrap" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "SteamTrap" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "SteamTrap" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "SteamTrap" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "SteamTrap" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "StraightwayValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "StraightwayValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "StraightwayValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "StraightwayValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "StraightwayValve" | "HeatTracingTypeAssignmentClass" | "ShutOffValve" | "The heat tracing type related to the , represented as a string. " | | true | | "StraightwayValve" | "InsulationTypeAssignmentClass" | "ShutOffValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "StraightwayValve" | "PipingClassCodeAssignmentClass" | "ShutOffValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "StraightwayValve" | "PipingComponentNameAssignmentClass" | "ShutOffValve" | "The piping component name of the ." | | true | | "StraightwayValve" | "PipingComponentNumberAssignmentClass" | "ShutOffValve" | "The piping component number of the ." | | true | | "Strainer" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "Strainer" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Strainer" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "Strainer" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "Strainer" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "Strainer" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "Strainer" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "Strainer" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "Strainer" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "SubTaggedColumnSection" | "SubTagNameAssignmentClass" | "SubTaggedColumnSection" | "The sub tag name of the ." | | true | | "SwingCheckValve" | "HeatTracingTypeAssignmentClass" | "CheckValve" | "The heat tracing type related to the , represented as a string. " | | true | | "SwingCheckValve" | "InsulationTypeAssignmentClass" | "CheckValve" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "SwingCheckValve" | "PipingClassCodeAssignmentClass" | "CheckValve" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "SwingCheckValve" | "PipingComponentNameAssignmentClass" | "CheckValve" | "The piping component name of the ." | | true | | "SwingCheckValve" | "PipingComponentNumberAssignmentClass" | "CheckValve" | "The piping component number of the ." | | true | | "SwingCheckValve" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "SwingCheckValve" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "SwingCheckValve" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "SwingCheckValve" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "TaggedColumnSection" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "TaggedColumnSection" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "TaggedColumnSection" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "TaggedColumnSection" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "TaggedPlantItem" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "TaggedPlantItem" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "TaggedPlantItem" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "TaggedPlantItem" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "Tank" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "Tank" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "Tank" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "Tank" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "Tank" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "ThinFilmEvaporator" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "ThinFilmEvaporator" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "ThinFilmEvaporator" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "ThinFilmEvaporator" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "ThinFilmEvaporator" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "Transmitter" | "DeviceTypeNameAssignmentClass" | "Transmitter" | "The device type of the ." | | true | | "Transmitter" | "SubTagNameAssignmentClass" | "Transmitter" | "The sub tag name of the ." | | true | | "TubeBundle" | "TubeMaterialOfConstructionCodeAssignmentClass" | "TubeBundle" | "A code that gives the material of construction of the tubes of the ." | | true | | "TubeBundle" | "TubeNominalDiameterNumericalValueRepresentationAssignmentClass" | "TubeBundle" | "A readable representation of the numerical value of the nominal diameter of the tubes. The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "TubeBundle" | "TubeNominalDiameterRepresentationAssignmentClass" | "TubeBundle" | "A readable representation of the nominal diameter of the tubes. The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "TubeBundle" | "TubeNominalDiameterTypeRepresentationAssignmentClass" | "TubeBundle" | "A readable representation of the type of the nominal diameter of the tubes. The purpose of this value is to give a textual representation of the nominal diameter to be used in the graphics of a PID." | | true | | "TurbineFlowMeter" | "HeatTracingTypeAssignmentClass" | "InlinePrimaryElement" | "The heat tracing type related to the , represented as a string. " | | true | | "TurbineFlowMeter" | "InsulationTypeAssignmentClass" | "InlinePrimaryElement" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "TurbineFlowMeter" | "PipingComponentNameAssignmentClass" | "InlinePrimaryElement" | "The piping component name of the ." | | true | | "TurbineFlowMeter" | "PipingComponentNumberAssignmentClass" | "InlinePrimaryElement" | "The piping component number of the ." | | true | | "TurbineFlowMeter" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "TurbineFlowMeter" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "TurbineFlowMeter" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "TurbineFlowMeter" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "VariableAreaFlowMeter" | "HeatTracingTypeAssignmentClass" | "InlinePrimaryElement" | "The heat tracing type related to the , represented as a string. " | | true | | "VariableAreaFlowMeter" | "InsulationTypeAssignmentClass" | "InlinePrimaryElement" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "VariableAreaFlowMeter" | "PipingComponentNameAssignmentClass" | "InlinePrimaryElement" | "The piping component name of the ." | | true | | "VariableAreaFlowMeter" | "PipingComponentNumberAssignmentClass" | "InlinePrimaryElement" | "The piping component number of the ." | | true | | "VariableAreaFlowMeter" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "VariableAreaFlowMeter" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "VariableAreaFlowMeter" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "VariableAreaFlowMeter" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "VentilationDevice" | "HeatTracingTypeAssignmentClass" | "PipeFitting" | "The heat tracing type related to the , represented as a string. " | | true | | "VentilationDevice" | "InsulationTypeAssignmentClass" | "PipeFitting" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "VentilationDevice" | "PipingClassCodeAssignmentClass" | "PipeFitting" | "The identification code of the piping class of the . So far, DEXPI does not define restrictions for valid values." | | true | | "VentilationDevice" | "PipingComponentNameAssignmentClass" | "PipeFitting" | "The piping component name of the ." | | true | | "VentilationDevice" | "PipingComponentNumberAssignmentClass" | "PipeFitting" | "The piping component number of the ." | | true | | "VentilationDevice" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "VentilationDevice" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "VentilationDevice" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "VentilationDevice" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "VenturiTube" | "HeatTracingTypeAssignmentClass" | "InlinePrimaryElement" | "The heat tracing type related to the , represented as a string. " | | true | | "VenturiTube" | "InsulationTypeAssignmentClass" | "InlinePrimaryElement" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "VenturiTube" | "PipingComponentNameAssignmentClass" | "InlinePrimaryElement" | "The piping component name of the ." | | true | | "VenturiTube" | "PipingComponentNumberAssignmentClass" | "InlinePrimaryElement" | "The piping component number of the ." | | true | | "VenturiTube" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "VenturiTube" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "VenturiTube" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "VenturiTube" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | | "Vessel" | "EquipmentDescriptionAssignmentClass" | "Equipment" | "A short desciption of the in natural language. So far, there is no support for descriptions in different languages." | | true | | "Vessel" | "TagNameAssignmentClass" | "TaggedPlantItem" | "The tag number of the . See also , , and ." | | false | | "Vessel" | "TagNamePrefixAssignmentClass" | "TaggedPlantItem" | "The prefix part of the tag number of the . For example, the prefix of the tag number \"P4714-A\" is \"P\". The prefix often indicates the type of the equipment item, e.g., \"P\" can indicate a pump. See also ." | | true | | "Vessel" | "TagNameSequenceNumberAssignmentClass" | "TaggedPlantItem" | "The sequence number part of the tag number of the . For example, the sequence number of the tag number \"P4714-A\" is \"4714\"." | | true | | "Vessel" | "TagNameSuffixAssignmentClass" | "TaggedPlantItem" | "The suffix part of the tag number of an item. For example, the suffix of the tag number \"P4714-A\" is \"A\"." | | true | | "VolumetricFlowDetector" | "HeatTracingTypeAssignmentClass" | "InlinePrimaryElement" | "The heat tracing type related to the , represented as a string. " | | true | | "VolumetricFlowDetector" | "InsulationTypeAssignmentClass" | "InlinePrimaryElement" | "The identification code for the insulation type related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "VolumetricFlowDetector" | "PipingComponentNameAssignmentClass" | "InlinePrimaryElement" | "The piping component name of the ." | | true | | "VolumetricFlowDetector" | "PipingComponentNumberAssignmentClass" | "InlinePrimaryElement" | "The piping component number of the ." | | true | | "VolumetricFlowDetector" | "BasfLineClassAssignmentClass" | "PipingComponent" | "The BASF line class of the , represented as a string. Note: This attribute has been included as an example for a company-specific attribute. It should actually be identified by a company-specific RDL reference. As there is currently no BASF RDL, the DEXPI RDL is used." | | true | | "VolumetricFlowDetector" | "FluidCodeAssignmentClass" | "PipingComponent" | "The identification code of the fluid related to the . So far, DEXPI does not define restrictions for valid values." | | true | | "VolumetricFlowDetector" | "NominalDiametersRepresentationAssignmentClass" | "PipingComponent" | "A readable representation of the nominal diameters of the ports of the . The purpose of this value is to give a textual representation of the nominal diameters to be used in the graphics of a PID." | | true | | "VolumetricFlowDetector" | "PressureTestCircuitNumberAssignmentClass" | "PipingComponent" | "The number of the pressure test circuit of the ." | | true | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------